Whirlpool Humidity Control Failure

Dehumidifier runs continuously and never reaches the set humidity

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty humidity sensor, Incorrect humidity calibration, Very leaky or damp space, Control board not responding to sensor input

How to Fix / Troubleshooting

Safety: Unplug before accessing internal sensors.

Steps to diagnose continuous running:

  • Verify actual humidity: Use a separate hygrometer to compare room humidity to the setpoint. If the room is actually at or below the setpoint, the unit should cycle off.
  • Check humidity sensor placement: Ensure the sensor is not touching the cold coil or located in a dead-air spot. It should be in the incoming air stream.
  • Inspect and test sensor: Check wiring and resistance of the humidity sensor. Replace if readings are out of range or do not change with humidity.
  • Control board: If the sensor is good but the unit never cycles off, the main control board may not be processing sensor data correctly and may need replacement.

Test: After sensor or board replacement, run the unit and confirm that it shuts off when the room reaches the set humidity.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidity Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.