F2
Whirlpool Keypad / Button Stuck or Shorted

Dehumidifier shows F2 and humidity setting cannot be adjusted correctly

Advertisements

Possible Causes

Stuck front panel button, Debris or moisture under keypad, Damaged keypad membrane, Shorted UI board traces

How to Fix / Troubleshooting

Safety: Unplug the unit before working on the control panel.

Steps to resolve F2:

  • Inspect buttons: Press each button several times. If one feels stuck or does not click, it may be jammed.
  • Clean around buttons: Use a soft cloth slightly dampened with mild detergent to clean the control panel surface. Do not allow liquid to seep into the panel.
  • Open the control panel: Remove screws and gently lift the panel to access the keypad membrane and UI board.
  • Check for moisture or corrosion: If moisture is present, dry the area thoroughly. Light corrosion on contacts can be cleaned with electronics contact cleaner.
  • Replace keypad/UI board if damaged: If the membrane is torn, bubbled, or buttons remain stuck, install a Whirlpool-compatible control panel or UI board assembly.

Test: Reassemble, restore power, and verify that all buttons respond normally and F2 is cleared.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Control Panel Keypad / User Interface Board
Check Price on Amazon

We may earn a commission from links on this page.