Possible Causes
Bucket full float stuck in up position, Bucket switch misaligned or broken, Debris blocking float movement, Faulty bucket full microswitch
How to Fix / Troubleshooting
Safety first: Unplug the unit before removing the bucket.
Steps to correct false bucket full:
- Inspect float: Remove the bucket and locate the float mechanism. Ensure it moves freely and is not jammed by dirt or scale.
- Clean float and cavity: Rinse the bucket and float assembly with warm water to remove buildup.
- Check switch actuator: Look inside the bucket compartment for the small lever or tab that the bucket presses. Make sure it is not bent or broken.
- Test with manual press: With the unit unplugged, gently press the bucket switch lever and listen for a click. If it feels mushy or does not click, the switch may be faulty.
If the problem persists, replacing the bucket full switch is usually required.