Whynter No Power / Dead Control Board

Dehumidifier will not power on at all; display is blank

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on control board, Faulty power cord, Failed main control board, Outlet not supplying power

How to Fix / Troubleshooting

Safety first: Ensure your hands are dry. Do not open the unit while it is plugged in.

Steps to troubleshoot no power:

  • Check outlet: Plug a lamp or other device into the same outlet to confirm it has power. Reset any tripped breaker or GFCI.
  • Inspect power cord: Look for cuts, burns, or kinks in the Whynter power cord. If damaged, discontinue use.
  • Try another outlet: Plug the unit directly into a different, known-good wall outlet (no extension cords).
  • Internal fuse check (advanced): If comfortable and after unplugging, remove the control panel cover and look for a small glass or ceramic fuse on the main control board. If visibly blown, it may be replaced with the exact same rating. If it blows again, a deeper fault exists.

If there is still no power after these checks, the main control board or power supply circuit is likely defective and should be serviced by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon