Adler
Overfilling / Water Level Control Failure
Adler ice maker continues to run water even when the reservoir is full, sometimes overflowing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck Adler water level float, Failed water level switch contacts welded closed, Control board not shutting off inlet valve, Debris preventing float from rising
How to Fix / Troubleshooting
Safety first: Unplug the unit and close the water supply valve to stop filling.
- Inspect float assembly: Access the Adler reservoir and verify the float moves freely without binding.
- Clean debris: Remove any scale or debris that could prevent the float from rising.
- Test level switch: Use a multimeter to check the switch contacts while moving the float; replace the Adler water level switch if it remains closed.
- Check control output: If the switch opens but the valve continues to energize, the main control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Adler Water Level Switch Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements