Water Temperature or Reservoir Thermistor Fault
E5 error code, ice production is very slow or stops completely, unit may run but not harvest ice.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed water reservoir thermistor, thermistor out of calibration, loose thermistor connection, control board sensing circuit failure
How to Fix / Troubleshooting
Safety First: Unplug the ice maker before testing components.
- Locate reservoir thermistor: On many Amana models, the thermistor is clipped to the water reservoir or inlet line.
- Inspect mounting: Ensure the thermistor is properly clipped and in contact with the reservoir surface, not dangling in air.
- Check wiring and connector: Trace the thermistor wires to the control board and reseat the connector. Look for corrosion or damage.
- Measure resistance: Disconnect the thermistor and measure resistance with a multimeter. Compare to the Amana service chart for the current water temperature. Replace if readings are open, shorted, or far out of range.
- Replace thermistor if needed: Install the new OEM thermistor, route wires away from sharp edges, and secure with clips or ties.
- Control board check: If a known-good thermistor still triggers E5, the main control board may have a failed sensor circuit and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Reservoir Thermistor
Check Price on Amazon