F1
Amana Water Inlet Valve or Fill Fault

F1 code on display, unit beeps and will not start ice cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed water inlet valve coil, clogged inlet screen, low household water pressure, kinked water supply line

How to Fix / Troubleshooting

Safety First: Unplug the ice maker and shut off the water supply before disconnecting any water lines.

  • Check water supply: Verify the household shutoff valve is fully open and the supply line is not kinked behind the unit.
  • Inspect inlet screen: Disconnect the water line from the inlet valve at the back of the unit. Remove and clean the small screen filter inside the valve using a soft brush.
  • Test valve coil: With power off, disconnect the valve wiring and measure coil resistance with a multimeter. Compare to the spec in the tech sheet. An open coil indicates a bad valve.
  • Check for flow: Briefly open the supply line into a bucket to confirm strong water flow from the house plumbing.
  • Replace inlet valve: If the coil is bad or the valve is stuck, remove mounting screws, swap in a new OEM Amana water inlet valve, reconnect tubing and wiring, and check for leaks.
  • Restore power and test: Turn water back on, restore power, and run a fill test in diagnostic mode if available.