F4
Amana
Hot Gas Valve or Defrost Circuit Error
F4 displayed, unit stops mid-cycle and may leave water on the evaporator plate.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed hot gas solenoid coil, restricted hot gas line, wiring issue to hot gas valve, control board output failure
How to Fix / Troubleshooting
Safety First: Unplug the unit. The hot gas valve is part of the sealed refrigeration system; do not open refrigerant lines.
- Locate hot gas valve: Typically mounted near the compressor with two refrigerant lines and an electrical coil.
- Inspect wiring: Check the coil wiring harness for loose connections or damage. Reseat the connector at the valve and control board.
- Test coil resistance: Disconnect the coil and measure resistance with a multimeter. Compare to the spec in the tech sheet. An open coil indicates a bad valve coil.
- Run diagnostic harvest test: In service mode, command a harvest and verify that the control board sends voltage to the hot gas valve coil.
- Replace coil/valve: If the coil is defective and removable, replace the coil. If the valve body itself is restricted or leaking, a sealed system technician must replace and recharge the system.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Hot Gas Valve Coil