Amana Low Ice Production

Ice maker makes ice but production is very slow, bin never fills completely.

Advertisements

Possible Causes

Dirty condenser coil, high ambient temperature, low water flow, partially restricted refrigerant system

How to Fix / Troubleshooting

Safety First: Unplug the unit before cleaning or servicing.

  • Clean condenser: Remove rear lower panel and clean the condenser coil thoroughly with a brush and vacuum.
  • Check ambient temperature: Ensure the room temperature is within the recommended range (typically 60–90°F). Very hot rooms reduce capacity.
  • Verify water flow: Check the inlet screen and supply line for restrictions. Ensure the reservoir fills quickly and maintains level.
  • Descale water system: Mineral buildup on the evaporator and in the reservoir can slow production. Run a manufacturer-approved ice machine cleaner through the system following the Amana instructions.
  • Monitor performance: After cleaning and adjustments, allow 24 hours for the bin to fill. If production remains low, a sealed system issue may exist and requires professional service.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Coil
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements