Amana No Ice Production

Ice maker runs but makes no ice at all, bin remains empty after 24 hours.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No water supply to unit, failed water inlet valve, failed circulation pump, refrigeration system failure (no cooling)

How to Fix / Troubleshooting

Safety First: Unplug the unit and shut off water before disconnecting lines.

  • Verify water supply: Confirm the shutoff valve is open and the supply line is not kinked. Disconnect at the unit and briefly open into a bucket to check flow.
  • Check reservoir fill: Restore power and observe whether the reservoir fills during startup. If not, test and replace the water inlet valve.
  • Check for cooling: After 15–20 minutes of operation, carefully feel the condenser coil (should be warm) and the evaporator plate (should be getting cold). If there is no cooling, a sealed system issue or compressor problem is likely.
  • Verify water circulation: Look inside during operation to see if water is flowing over the evaporator plate. If not, test and replace the circulation pump.
  • Call a technician for sealed system: If water supply and pumps are good but there is no cooling, contact a certified technician for compressor/refrigerant diagnosis.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Inlet Valve