Insufficient Bin Cooling or Insulation Issue
Ice melts quickly in the bin; bin temperature feels too warm
Advertisements
Possible Causes
Door gasket not sealing, Warm air leaks around bin, Failed bin thermistor, Poor ventilation around unit
How to Fix / Troubleshooting
Safety First: Unplug before gasket or sensor replacement.
Steps:
- Inspect gasket: Check the bin door gasket for tears, gaps, or deformation. Replace if damaged.
- Check closure: Ensure the door closes fully and latches properly.
- Test bin sensor: If equipped, test the bin thermistor and replace if out of spec.
- Ventilation: Improve airflow around the unit to help maintain bin temperature.