Arktic
Control or Thermal Protection Cycling
Unit short cycles; frequently starts and stops within a few minutes
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheating compressor, Faulty overload protector, Erratic temperature sensor, Control board logic fault
How to Fix / Troubleshooting
Safety First: Unplug before accessing compressor or sensors.
Steps:
- Improve cooling: Clean condenser and ensure fan operation to reduce compressor temperature.
- Check overload: Inspect the compressor overload protector; replace if it trips at normal temperatures.
- Test sensors: Verify thermistors are within spec and replace any that are erratic.
- Control board: If short cycling persists, the main control PCB may be defective.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Overload Protector
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements