E19
Asko
EEPROM or Memory Error in Control Board
E19 error; unit may not respond to commands or may lock up mid-cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted control memory, Power surge damage, Faulty main control PCB, Poor grounding of appliance
How to Fix / Troubleshooting
Safety first: Disconnect power before any inspection.
- Power cycle: Unplug the ice maker for 10 minutes, then plug back in to see if the error clears.
- Check grounding: Ensure the outlet is properly grounded and that the Asko ice maker's plug is fully inserted. Avoid using extension cords.
- Surge protection: If the error followed a storm or outage, consider using a surge protector for future protection.
- Board replacement: If E19 reappears immediately or frequently, the main control PCB's memory is likely damaged and the board should be replaced by a technician.