Avanti Hollow Ice Cubes / Fast Freeze with Low Water

Avanti ice maker makes ice but cubes are hollow or have large holes in the center.

Advertisements

Possible Causes

Low water pressure to inlet valve, partially clogged inlet screen, water level set too low, short freeze cycle due to sensor miscalibration

How to Fix / Troubleshooting

Safety: Shut off water and unplug before disconnecting lines.

Steps:

  • 1. Check water pressure: Ensure the supply line is not kinked and that household water pressure is adequate (typically 20–120 psi).
  • 2. Clean inlet screen: Remove and clean the inlet valve screen to restore full flow.
  • 3. Inspect reservoir level: Confirm the reservoir fills to the correct level. Clean the float or level sensor if it is sticking.
  • 4. Adjust thickness setting: If your model allows, increase the ice thickness setting so cubes freeze more completely.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Inlet Valve
Check Price on Amazon