Possible Causes
Stuck or shorted clean button, control board firmware glitch, keypad membrane failure, water level sensor not detecting end of clean cycle
How to Fix / Troubleshooting
Safety: Unplug before removing the control panel.
Steps:
- 1. Attempt manual exit: Follow the user manual procedure to exit cleaning mode (usually pressing and holding a specific button).
- 2. Power reset: Unplug for 10 minutes, then plug back in and see if the unit returns to normal mode.
- 3. Inspect keypad: Remove the control panel and check for moisture or corrosion on the keypad connector. Dry and reseat.
- 4. Test buttons: Press each button and feel for proper click. If the clean button feels stuck or always registers, the keypad assembly may need replacement.
- 5. Replace control board: If the issue persists, replace the main control board or user interface board as specified for your Avanti model.