E3
Avanti
Ambient Temperature Sensor Fault
Display shows E3, ice production stops, unit may start then shut off after a short time.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ambient thermistor on control panel, loose or corroded sensor connector, damaged sensor harness, defective main control PCB
How to Fix / Troubleshooting
Safety: Unplug the ice maker before removing the control panel or top cover.
How to check:
- 1. Verify installation environment: Ensure the unit is not installed outdoors or in extreme temperatures outside Avanti's specified range (typically 50–100°F). Extreme ambient conditions can trigger E3 on some models.
- 2. Access the control panel: Remove screws securing the front control panel or top cover. Carefully pull the panel forward to expose the wiring.
- 3. Locate ambient sensor: Look for a small thermistor mounted near the air intake or behind the control panel with two wires going to the main board.
- 4. Inspect connections: Confirm the sensor connector is fully seated on the board. Check for corrosion or moisture on the plug and pins. Dry any condensation and reseat the connector.
- 5. Test sensor: Disconnect the sensor and measure resistance at room temperature. Compare to the service manual chart. Replace if reading is open, shorted, or far out of range.
- 6. Replace control board if needed: If the sensor tests correctly and wiring is good, the main control PCB may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5