E9
Avanti Low Refrigerant / Refrigeration System Performance Fault (Temperature Not Reached)

Display shows E9, unit may run briefly then stop; ice production is halted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in evaporator or tubing, weak compressor, blocked capillary tube, severely dirty condenser coil, failed condenser fan

How to Fix / Troubleshooting

Safety: Do not attempt to open the sealed refrigeration system yourself. Refrigerant handling requires EPA-certified technicians.

User-level checks:

  • 1. Clean condenser coil: Unplug the unit and remove the rear panel. Use a soft brush and vacuum to thoroughly clean the condenser coil fins.
  • 2. Verify fan operation: Restore power and confirm the condenser fan runs whenever the compressor is on. Replace the fan motor if it does not run.
  • 3. Check installation conditions: Ensure the unit is not installed in a very hot, enclosed space. Provide adequate ventilation per Avanti's installation instructions.
  • 4. Observe evaporator frost pattern: With the panel removed, run the unit and watch the evaporator. A normal system will frost evenly across most of the coil. A partial frost pattern or no frost may indicate low refrigerant or a restriction.
  • 5. Call a professional: If cleaning and airflow checks do not clear E9 and the unit still fails to cool properly, contact a qualified refrigeration technician to check for leaks, recharge, or replace the compressor.
Advertisements

Repair Difficulty

Professional Required 5/5