E08
Balay Water Fill Level or Flow Sensor Error

E08 displayed; ice bin is empty even though the unit appears to run; no water reaches the evaporator tray.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective water level sensor, Scale buildup on level probe, Loose sensor wiring, Faulty control board water level circuit

How to Fix / Troubleshooting

Safety first: Disconnect power and close the water supply.

  • Locate level sensor: On many Balay ice makers, a water level probe or float is installed in the reservoir or sump.
  • Clean sensor: Remove mineral scale from the probe or float using a soft brush and a food-safe descaling solution. Rinse thoroughly with clean water.
  • Check movement: If a float is used, ensure it moves freely up and down without sticking.
  • Inspect wiring: Verify that the sensor harness is intact and firmly connected to the control PCB.
  • Replace sensor: If cleaning does not resolve the issue and the sensor tests open/shorted with a multimeter, replace the water level sensor assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Level Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements