E10
Balay Refrigeration System Performance Fault

E10 displayed; unit runs continuously but ice production is very low or zero; cabinet feels warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge, Blocked capillary tube, Inefficient compressor, Condenser coil heavily clogged

How to Fix / Troubleshooting

Safety first: Disconnect power before cleaning or inspecting internal components.

  • Clean condenser: Pull the Balay ice maker away from the wall. Use a soft brush and vacuum to thoroughly clean dust and lint from the condenser coil and fan area.
  • Check condenser fan: Confirm the fan runs smoothly when the unit is powered. Replace the fan motor if it does not start or is noisy.
  • Ventilation: Ensure there is adequate clearance around the unit as specified in the Balay installation manual to allow proper airflow.
  • Refrigerant issues: If the condenser is clean and the fan operates but cooling remains poor, the sealed system may be undercharged or restricted. This requires a certified technician to check pressures, locate leaks, and recharge or repair the system.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Coil