Balay
Excessive Water Fill / Overfreezing
Ice cubes are too large, thick, or fused together on the evaporator grid.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck water inlet valve, Incorrect ice thickness calibration, Faulty water level sensor, Control board not terminating freeze cycle
How to Fix / Troubleshooting
Safety first: Unplug the unit and close the water supply.
- Inspect cubes: Remove large slabs of ice from the bin and evaporator using a plastic tool.
- Check valve operation: With power briefly applied, observe the fill cycle. If water continues to flow after the fill period, replace the inlet valve.
- Adjust thickness: Use the Balay control to reduce ice thickness or harvest time if adjustable.
- Sensor check: Inspect and clean the water level sensor or probe; replace if it misreads the level.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements