E10
Bauknecht Drain Pan Overflow / Leak Detection

E10 error, water present in base pan, unit may shut down or alarm, internal pump may run continuously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged internal drain hose, Failed condensate drain pump (if equipped), Water leak from inlet tubing or valve

How to Fix / Troubleshooting

Safety: Disconnect power and close the water supply valve.

Procedure:

  • Inspect base pan: Remove the front kick plate or rear panel to view the base. Mop up any standing water with towels.
  • Check drain outlet: Locate the internal drain hose from the evaporator tray to the base or external drain. Clear any slime, ice, or debris using a flexible brush or pipe cleaner.
  • Test drain pump (if fitted): Pour a small amount of water into the internal sump and reconnect power briefly to see if the pump evacuates water. If the pump hums but does not pump, or is silent with voltage present, replace the pump.
  • Inspect for leaks: Examine the water inlet valve, tubing, and connections for drips while the water supply is on. Tighten fittings or replace cracked tubing.
  • Reset error: After resolving the cause and drying the leak sensor area, unplug the unit for 5–10 minutes, then restart.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Drain Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements