E13
Bauknecht
User Interface / Keypad Communication Error
E13 displayed, keypad or touch controls unresponsive or erratic.
Advertisements
Possible Causes
Faulty touch control panel, Loose ribbon cable between UI and main PCB, Moisture ingress behind control panel
How to Fix / Troubleshooting
Safety: Unplug the ice maker before removing the control panel.
Steps:
- Inspect control area: Check for signs of condensation or water behind the display or buttons. Dry gently with a soft cloth.
- Reseat ribbon cable: Remove the front control panel and carefully disconnect and reconnect the flat ribbon cable to the main PCB. Ensure it is fully seated and locked.
- Check for damage: Look for cracks in the touch panel, worn buttons, or corrosion on connectors.
- Replace UI board: If buttons remain unresponsive or random inputs occur, replace the Bauknecht user interface / keypad assembly.
After reassembly, restore power and test all buttons and functions.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
User Interface Control Panel
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements