E13
Bauknecht User Interface / Keypad Communication Error

E13 displayed, keypad or touch controls unresponsive or erratic.

Advertisements

Possible Causes

Faulty touch control panel, Loose ribbon cable between UI and main PCB, Moisture ingress behind control panel

How to Fix / Troubleshooting

Safety: Unplug the ice maker before removing the control panel.

Steps:

  • Inspect control area: Check for signs of condensation or water behind the display or buttons. Dry gently with a soft cloth.
  • Reseat ribbon cable: Remove the front control panel and carefully disconnect and reconnect the flat ribbon cable to the main PCB. Ensure it is fully seated and locked.
  • Check for damage: Look for cracks in the touch panel, worn buttons, or corrosion on connectors.
  • Replace UI board: If buttons remain unresponsive or random inputs occur, replace the Bauknecht user interface / keypad assembly.

After reassembly, restore power and test all buttons and functions.