E16
Bauknecht Sensor Calibration / Out-of-Range Error

E16 error, unit beeps and stops, internal temperature sensor readings appear inconsistent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor drift out of tolerance, Poor sensor mounting causing incorrect readings, Control board ADC fault

How to Fix / Troubleshooting

Safety: Unplug the appliance.

Steps:

  • Check all NTC sensors: Measure resistance of evaporator and cabinet sensors at a known temperature and compare to Bauknecht specifications.
  • Verify mounting: Ensure sensors are firmly attached to surfaces (evaporator plate, cabinet wall) with clips or thermal paste as originally installed.
  • Replace suspect sensors: If any sensor is significantly out of spec, replace it with the correct Bauknecht part.
  • Control board: If all sensors are within tolerance but E16 persists, the main control PCB may have an internal measurement fault and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature Sensors Set
Check Price on Amazon

We may earn a commission from links on this page.