E19
Bosch
Control Board Configuration / EEPROM Fault
E19 error; internal memory or configuration fault affecting ice maker operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted control board firmware, Failed EEPROM on main PCB, Incorrect configuration after board replacement
How to Fix / Troubleshooting
Safety: Disconnect power before handling the control board.
- Power reset: Turn off the appliance at the breaker or unplug for at least 10 minutes, then restore power to see if the error clears.
- Check for recent repairs: If a control board was recently replaced, verify that the correct Bosch part number was installed and that any configuration steps in the service manual were completed.
- Firmware update (if available): Some Bosch models allow firmware updates via service tools. This must be performed by an authorized technician.
- Replace control board: If E19 persists, replace the main control board with the correct Bosch OEM part. Label all connectors, swap boards, and reassemble.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Bosch Main Control Board
Check Price on Amazon