E17
Café High Pressure / Condenser Overheat Protection

E17 error; unit may shut down shortly after startup with minimal compressor run time.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser airflow, Failed condenser fan motor, Excessive ambient temperature around built-in unit, Overcharged or restricted sealed system (requires pro service)

How to Fix / Troubleshooting

Safety First: Unplug the ice maker. Components near the condenser can be hot; allow cooling time.

Steps:

  • Improve ventilation: Ensure cabinetry cutout and toe-kick openings meet Café installation specs. Remove any items blocking airflow.
  • Clean condenser: Vacuum and brush the condenser coils thoroughly.
  • Check condenser fan: Verify the fan spins freely by hand. If stiff or noisy, replace the fan motor.
  • Observe operation: Restore power and confirm the fan runs whenever the compressor is on.
  • If E17 persists: A sealed system issue may be causing high pressure. Contact a qualified refrigeration technician for further diagnosis.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements