E16
Candy Auxiliary Circuit / Low Voltage Supply Fault

E16 displayed; internal light or auxiliary functions fail while main cooling still works.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage power supply on PCB, Shorted internal LED light module, Damaged wiring to auxiliary components, Blown low-voltage fuse on control board

How to Fix / Troubleshooting

Safety first: Disconnect power before opening any panels.

  • Check internal light: If the internal LED is shorted, it can pull down the low-voltage rail. Disconnect the light module and see if E16 clears after a reset.
  • Inspect PCB fuses: Some Candy boards include small fuses for low-voltage circuits. Replace only with identical ratings if blown.
  • Look for burnt components: Examine the PCB for burnt resistors or regulators in the low-voltage section. If found, the board should be replaced.
  • Test wiring: Inspect harnesses to lights, fans, and sensors for shorts to chassis or each other.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements