E9
Clatronic Overtemperature / overheat protection triggered

E9 error displayed; unit may start then quickly stop with beeping.

Advertisements

Possible Causes

Blocked condenser airflow, Failed condenser fan motor, High ambient temperature above design limit, Overheating main PCB or compressor

How to Fix / Troubleshooting

Safety first: Turn off and unplug the ice maker. Allow it to cool for at least 30 minutes before further inspection.

  • Improve ventilation: Ensure the ice maker is placed in a well‑ventilated area, away from direct sunlight, ovens, or radiators. Maintain at least 10–15 cm clearance on all sides and the back.
  • Clean condenser and fan: Remove the rear cover and gently vacuum dust from the condenser coil and fan blades. Use a soft brush to avoid bending fins.
  • Check fan operation: Plug the unit back in and briefly start a cycle while observing the fan (keep fingers clear). If the fan does not spin or is noisy, replace the condenser fan motor.
  • Ambient temperature: Verify that the room temperature is within the specified range in the Clatronic manual (typically 10–32 °C). Move the unit if necessary.
  • PCB thermal sensor: Some models have a thermal sensor on the PCB or compressor. Ensure it is properly attached and not covered with dust. If damaged, replace the sensor or PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements