Clatronic Cycle control / timing fault

Ice maker runs continuously without cycling properly; ice production is irregular.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty evaporator temperature sensor, Stuck relay on main PCB, Firmware error, Scale buildup affecting ice release timing

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing internal components.

  • Descale evaporator: Clean and descale the evaporator to ensure ice releases at the correct time.
  • Reset control: Perform a full power reset by unplugging for 15 minutes.
  • Sensor replacement: If cycles are excessively long or short, replace the evaporator NTC sensor.
  • PCB evaluation: If the compressor or pump runs continuously without proper cycling, the main PCB relay may be stuck. Replace the PCB if confirmed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon