Danby No Cooling / Sealed System Failure

Danby ice maker runs but makes no ice; evaporator plate does not get cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loss of refrigerant charge, Blocked capillary tube, Weak or failed compressor, Non‑running condenser fan motor

How to Fix / Troubleshooting

Safety first: Unplug the unit before touching internal components. Sealed system repairs require a licensed technician.

Basic checks:

  • Listen for compressor: When the unit is running, place your hand on the side or back to feel for compressor vibration and a low hum. Silence may indicate a failed compressor or start device.
  • Check condenser fan: Confirm the fan near the condenser is spinning when the compressor is on. If not, test and replace the fan motor.
  • Feel the condenser: After several minutes of operation, the condenser coils should feel warm. If they remain cool and the compressor is running, there may be a refrigerant issue.
  • Inspect for oily residue: Look for oil stains on tubing or joints, which can indicate a refrigerant leak.

Next steps: If the compressor runs but there is no cooling, or if you suspect a leak, contact an authorized Danby service technician for sealed system diagnosis and repair.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor or Sealed System Components
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements