E8
Danby
Water Pump Failure / Pump Circuit Error
Danby ice maker displays E8; water pump does not circulate water over the evaporator.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed circulation pump motor, Blocked pump inlet screen, Airlock in pump, Loose or burnt pump wiring connector
How to Fix / Troubleshooting
Safety first: Unplug the ice maker and drain water from the reservoir before removing the pump.
Steps to troubleshoot E8:
- Check water level and seating: Ensure the reservoir is properly seated and filled to the correct level. Some Danby models will not run the pump if the reservoir is not fully inserted.
- Inspect the pump intake: Remove the ice basket and internal cover to access the pump. Look for debris or scale blocking the pump inlet or filter screen. Clean with a soft brush and water.
- Bleed air from the pump: After cleaning, fill the reservoir and gently tap the pump housing to release trapped air. Some models benefit from tilting the unit slightly to help purge air.
- Check wiring: Access the pump wiring from the underside or rear. Ensure the connector is firmly attached to the harness and control board. Look for signs of overheating or corrosion.
- Test the pump motor: With the unit unplugged, measure the pump motor resistance. An open circuit indicates a failed motor. If safe and within your skill level, you can briefly power the pump with a test cord (matching its voltage) to confirm operation.
- Replace the pump: If the pump is defective, order the correct Danby water circulation pump. Disconnect hoses (have towels ready), swap the pump, and secure all clamps tightly to prevent leaks.
- Reassemble and test: Refill the reservoir, restore power, and run a cycle. Confirm that water flows over the evaporator and E8 does not reappear.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements