E17
De Dietrich Plate Temperature Sensor or Compressor Control Fault

E17 displayed, ice maker stops and water remains on evaporator plate without freezing

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective evaporator thermistor, Loose thermistor connection, Faulty compressor relay on PCB, Incorrect sensor calibration

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the evaporator area or control board.

Diagnostic steps:

  • Check evaporator thermistor: Locate the evaporator thermistor attached to the plate. Ensure it is firmly clipped and not hanging loose.
  • Measure resistance: With the unit at room temperature, measure thermistor resistance and compare to De Dietrich specifications. Replace if readings are far off.
  • Inspect wiring: Trace the thermistor harness back to the control board. Look for pinched wires or loose connectors.
  • Control board relay: On the main PCB, inspect the compressor relay for signs of overheating. If the relay does not energize despite correct sensor readings, the board may be faulty.

Note: Sensor replacement is usually straightforward. If board-level faults are suspected, professional service is recommended.

Advertisements

Repair Difficulty

Medium 3/5

Required Part