E10
Fagor
Ambient Thermistor Circuit Fault
Ambient temperature sensor error; unit may not start or runs erratically.
Advertisements
Possible Causes
Defective ambient temperature sensor, Damaged sensor harness, Corroded connector at control PCB, Control board analog input failure
How to Fix / Troubleshooting
Safety: Unplug the ice maker before accessing internal components.
- Find the ambient sensor: This sensor is typically mounted near the air intake or behind the front grille to sense room temperature.
- Visual inspection: Check that the sensor body is intact and not covered in dust or ice. Ensure it is not touching hot components.
- Measure resistance: Disconnect the sensor and measure its resistance. Compare to the Fagor temperature‑resistance chart. Replace if readings are far outside expected values.
- Inspect wiring and connectors: Look for loose plugs or damaged insulation. Repair or replace as needed.
After replacing the sensor, reset the unit and verify that it starts and cycles normally without re‑displaying E10.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor
Check Price on Amazon