E15
Fagor Compressor Thermal Protection Trip

Compressor overheat or high compressor temperature alarm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser airflow, Failed condenser fan motor, Overcharged or undercharged refrigerant, Defective compressor internal overload

How to Fix / Troubleshooting

Safety: Allow the compressor to cool and disconnect power before touching it.

  • Improve ventilation: Ensure the unit has proper clearance and that vents are not blocked by cabinets or other appliances.
  • Clean condenser coil: Remove dust and lint as described in previous steps for high temperature faults.
  • Check condenser fan: Verify that the fan runs whenever the compressor is on. Replace the fan motor if it is not operating correctly.
  • Let the compressor cool: Leave the unit off for at least 30–60 minutes to allow the internal overload to reset, then restart and monitor.

If the compressor overheats again quickly, a sealed system or compressor fault is likely and should be handled by a refrigeration technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements