E15
Fagor
Compressor Thermal Protection Trip
Compressor overheat or high compressor temperature alarm.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser airflow, Failed condenser fan motor, Overcharged or undercharged refrigerant, Defective compressor internal overload
How to Fix / Troubleshooting
Safety: Allow the compressor to cool and disconnect power before touching it.
- Improve ventilation: Ensure the unit has proper clearance and that vents are not blocked by cabinets or other appliances.
- Clean condenser coil: Remove dust and lint as described in previous steps for high temperature faults.
- Check condenser fan: Verify that the fan runs whenever the compressor is on. Replace the fan motor if it is not operating correctly.
- Let the compressor cool: Leave the unit off for at least 30–60 minutes to allow the internal overload to reset, then restart and monitor.
If the compressor overheats again quickly, a sealed system or compressor fault is likely and should be handled by a refrigeration technician.