E16
Fagor
Fan Motor or Fan Control Failure
Fan motor error; condenser or evaporator fan not detected or stalled.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed condenser fan motor, Obstructed fan blades, Faulty fan relay on control PCB, Loose fan wiring connector
How to Fix / Troubleshooting
Safety: Unplug the unit before working near moving parts.
- Access the fan: Remove the rear or side panel to expose the condenser fan assembly.
- Check for obstructions: Remove any plastic wrap, insulation, or debris caught in the fan blades.
- Spin test: Rotate the fan blade by hand. It should move freely without grinding. If stiff or seized, replace the fan motor.
- Verify wiring: Ensure the fan connector is fully seated on the control board and that wires are not damaged.
- Test voltage: If qualified, measure voltage at the fan terminals when the compressor is running. If voltage is present but the fan does not run, replace the motor. If no voltage, suspect the control board.
After repair, reassemble panels and confirm that the fan runs reliably during operation.