Fagor Insufficient Water Fill or Premature Harvest

Ice cubes are too small, thin, or hollow.

Advertisements

Possible Causes

Partially clogged water inlet valve, Misadjusted ice thickness probe, Low water pressure, Scale buildup on water distribution system

How to Fix / Troubleshooting

Safety: Turn off water and power before disassembly.

  • Check water pressure and flow: Confirm strong flow at the supply line. Clean the inlet valve screen and replace any clogged external filters.
  • Clean water distribution: Remove and clean the spray bar or water curtain that distributes water over the evaporator. Use descaler to remove mineral deposits.
  • Adjust thickness probe: Slightly increase the target thickness per the service manual so the unit waits longer before harvest.

After adjustments, observe several cycles to confirm cube size has improved.