Fagor No Ice Production

Ice maker runs but produces no ice at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Water supply turned off, Failed water inlet valve, Severely scaled evaporator plate, Low refrigerant charge in sealed system

How to Fix / Troubleshooting

Safety: Disconnect power and close the water supply before internal inspection.

  • Verify water supply: Confirm the shutoff valve is open and that water flows freely to the inlet of the ice maker.
  • Check for fill: Start a cycle and listen for the water fill. If you do not hear water entering, test and replace the water inlet valve as needed.
  • Inspect evaporator for scale: Remove the front panel and look at the evaporator plate. Heavy white or green mineral deposits can prevent ice formation. Run a full descaling cycle with Fagor‑approved cleaner.
  • Observe frost pattern: After 10–15 minutes of operation, check if the evaporator is frosting evenly. If not, a sealed system issue may be present and requires a refrigeration technician.

Address water and scale issues first; if there is still no ice, seek professional sealed system service.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements