d1
Frigidaire Drain / Fill Sequence Error

Frigidaire ice maker displays d1 and drains continuously or fails to fill

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck drain pump relay on control board, Faulty water level sensor, Control board software glitch, Shorted wiring to pump

How to Fix / Troubleshooting

Safety: Unplug the unit before inspection.

Basic checks:

  • Inspect the wiring harness to the drain pump for signs of rubbing or shorting to the cabinet.
  • Disconnect the pump connector and check if the pump stops running (if it was stuck on). If it continues, the issue is on the board.
  • Power-cycle the unit for 5–10 minutes to reset the control.
  • If the pump only runs when commanded but the code persists, test the water level sensor or float switch and replace if faulty.
  • If the pump runs continuously whenever power is applied, the control board drain relay is likely stuck and the board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon