F2
Frigidaire Evaporator Plate Temperature / Freeze Time Error

Frigidaire ice maker shows F2 and ice is thin or incomplete

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator thermistor out of range, Poor contact between thermistor and plate, Partial refrigerant restriction, Control board timing fault

How to Fix / Troubleshooting

Safety: Disconnect power before removing interior panels.

Check evaporator sensor and plate:

  • Open the ice maker and locate the evaporator plate where ice forms.
  • Find the thermistor or temperature sensor attached to the plate.
  • Ensure the sensor is firmly attached and making good contact with the metal surface. Reclip or reattach if loose.
  • Inspect wiring for damage and reseat the connector at the control board.
  • Test the thermistor resistance and compare to the tech sheet. Replace if out of specification.
  • After replacement, restore power and run a full cycle to see if ice thickness returns to normal and F2 clears.

If the problem persists: A sealed system issue or control board fault may be present and should be evaluated by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements