E14
GE Profile
Hot Gas Valve / Defrost Valve Fault
E14 displayed; unit may not defrost properly or may show irregular ice formation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed hot gas solenoid coil, Stuck hot gas valve, Wiring issue to hot gas valve, Control board not energizing valve
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing the refrigeration components. Do not attempt to open sealed system lines.
- Step 1 – Locate hot gas valve: This solenoid valve is typically near the compressor and condenser, connected to small copper lines.
- Step 2 – Inspect wiring: Check the valve coil wiring for loose connections or damage. Reseat connectors.
- Step 3 – Test coil resistance: With a multimeter, measure the coil resistance and compare to GE specifications. An open coil indicates a failed valve coil.
- Step 4 – Listen for valve operation: During a harvest/defrost cycle (refer to service mode), you should hear a click when the valve is energized. If not, and voltage is present, the valve may be stuck.
- Step 5 – Replace hot gas valve: If the coil is open or the valve is stuck, a sealed system technician must recover refrigerant, replace the valve, evacuate, and recharge the system.
- Step 6 – Control board check: If the valve and wiring are good but never receive power, the control board may be defective and require replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Advertisements