E18
GE Profile
Accessory Output Fault (e.g., Internal Light Circuit)
E18 code; unit may not recognize or control the internal light or auxiliary components.
Advertisements
Possible Causes
Shorted internal LED light, Damaged light wiring, Control board accessory driver failure, Moisture causing short in accessory circuit
How to Fix / Troubleshooting
Safety first: Unplug the ice maker before working on lighting or accessory circuits.
- Step 1 – Inspect internal light: Check the internal LED or bulb for visible damage, moisture, or corrosion at the socket.
- Step 2 – Disconnect accessory: Temporarily disconnect the light or accessory from its harness and restore power to see if E18 clears. If it does, the accessory is likely shorted.
- Step 3 – Check wiring: Inspect the accessory wiring for pinched or bare wires that could short to the cabinet.
- Step 4 – Replace accessory: Install a new GE-approved light module or accessory if the original is defective.
- Step 5 – Control board check: If E18 persists with the accessory disconnected and wiring intact, the control board output driver may be damaged and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Internal LED Light Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements