E18
GE Profile Accessory Output Fault (e.g., Internal Light Circuit)

E18 code; unit may not recognize or control the internal light or auxiliary components.

Advertisements

Possible Causes

Shorted internal LED light, Damaged light wiring, Control board accessory driver failure, Moisture causing short in accessory circuit

How to Fix / Troubleshooting

Safety first: Unplug the ice maker before working on lighting or accessory circuits.

  • Step 1 – Inspect internal light: Check the internal LED or bulb for visible damage, moisture, or corrosion at the socket.
  • Step 2 – Disconnect accessory: Temporarily disconnect the light or accessory from its harness and restore power to see if E18 clears. If it does, the accessory is likely shorted.
  • Step 3 – Check wiring: Inspect the accessory wiring for pinched or bare wires that could short to the cabinet.
  • Step 4 – Replace accessory: Install a new GE-approved light module or accessory if the original is defective.
  • Step 5 – Control board check: If E18 persists with the accessory disconnected and wiring intact, the control board output driver may be damaged and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Internal LED Light Assembly
Check Price on Amazon

We may earn a commission from links on this page.