GE Profile
Bin Full Detection Failure
Ice maker bin is full of ice, but the unit continues to run and overfill.
Advertisements
Possible Causes
Blocked or failed bin full sensor, Misaligned bin arm, Control board ignoring full signal, Sensor lens covered with frost
How to Fix / Troubleshooting
Safety first: Unplug the unit before working in the bin area.
- Step 1 – Clear bin: Remove excess ice and ensure no large clumps are blocking the sensor or arm.
- Step 2 – Clean sensor: Wipe optical sensors or mechanical switches with a soft cloth to remove frost and debris.
- Step 3 – Check alignment: Verify the sensor or arm is positioned correctly relative to the bin. Adjust brackets if bent.
- Step 4 – Test sensor: Use a multimeter or diagnostic mode to confirm the sensor changes state when the bin is full. Replace if it does not.