GE Profile Premature Shutdown

Ice maker turns on but shuts off after a short time without making ice.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating due to blocked airflow, Faulty thermistor reporting incorrect temperature, Bin full sensor stuck in full position, Control board fault

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning or accessing sensors.

  • Step 1 – Check ventilation: Ensure front grille and rear vents are not blocked by cabinets or debris. Clean the condenser coil.
  • Step 2 – Empty bin: Remove all ice and verify the bin full sensor or arm moves freely and is not stuck in the full position.
  • Step 3 – Inspect thermistors: Check that evaporator and bin thermistors are properly mounted and not loose or damaged.
  • Step 4 – Run diagnostic mode: If your GE Profile model supports diagnostics, enter test mode to check sensor readings. Replace any sensor that reads out of range.
  • Step 5 – Replace control board: If sensors and airflow are correct but shutdown persists, the control board may be faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ice Bin Full Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements