E18
Gorenje Defrost / Harvest Timing Error

Display shows E18; unit may freeze excessively or not reach correct ice thickness, with abnormal cycle times.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect defrost timing from PCB, Faulty cycle timer circuit, Sticking relay controlling harvest heater, Software fault in control board

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the control board.

  • Reset control: Unplug the ice maker for at least 5 minutes to allow the control to fully reset, then reconnect and observe operation.
  • Check sensors first: Verify that evaporator and thickness sensors (E4/E5 related) are functioning correctly, as bad inputs can cause timing errors.
  • Inspect relays: On the main PCB, look for relays with heat discoloration or cracked solder joints. Resolder or replace the board if necessary.
  • Update or replace PCB: If E18 persists and all sensors and loads are good, the control logic may be faulty. Replace the main control PCB with the correct Gorenje part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon