Gorenje Intermittent Power or Overheat Shutdown

Ice maker starts a cycle but stops midway and shuts off without any error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating compressor with thermal cutout, Loose mains connection, Failing main control PCB, Blocked condenser airflow

How to Fix / Troubleshooting

Safety first: Unplug the unit before inspecting electrical or compressor components.

  • Clean condenser and ensure airflow: Remove dust from the condenser coil and verify that the fan runs freely.
  • Check ambient temperature: Ensure the unit is not installed in a very hot, enclosed space.
  • Inspect mains connections: Tighten screws on the terminal block and check the plug and cord for signs of arcing.
  • Monitor compressor: After restarting, feel the compressor casing periodically. If it becomes extremely hot and then the unit shuts off, the compressor or start components may be failing and require professional diagnosis.
  • Replace PCB if necessary: If power and cooling components are good but shutdowns persist, the main control board may be intermittently failing.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon