E17
Grundig Water Flow Meter or Fill Timing Fault

Ice maker shows a flow meter or water volume error, inconsistent cube size

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty water flow meter (turbine sensor), Blocked flow meter by debris, Incorrectly installed water filter, Control board miscalibration

How to Fix / Troubleshooting

Safety first: Turn off water and power before disconnecting any water lines.

Steps to check:

  • Locate flow meter: On some Grundig models, a small plastic flow sensor is installed in-line with the inlet hose. Inspect for kinks or bends around it.
  • Check for debris: Remove the flow meter and look for sediment or scale blocking the turbine. Rinse thoroughly under running water.
  • Verify filter installation: Ensure the water filter is fully seated and not restricting flow. Replace if old or clogged.
  • Reassemble and test: Reinstall the flow meter with correct flow direction (arrow on body). Restore water and power, then run a test cycle to see if cube size normalizes.

Note: If the error persists, the flow meter or main control board may need replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Grundig Water Flow Meter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements