E11
Hansa Refrigeration System Underperformance / Low Refrigerant or Blockage

Ice maker shows E11; evaporator temperature remains too high and no ice forms even though the compressor runs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to leak, Restricted capillary tube or filter-drier, Weak compressor, Faulty evaporator thermistor misreading temperature

How to Fix / Troubleshooting

Safety first: Unplug the unit. Refrigeration system work must be performed by a certified technician.

  • Basic airflow checks: Ensure the condenser coil is clean and the condenser fan is operating correctly. Poor heat rejection can mimic low refrigerant symptoms.
  • Inspect for oil stains: Look around tubing joints, the evaporator, and condenser for oily residue indicating a refrigerant leak.
  • Check evaporator frost pattern: With a technician present, observe the evaporator. A partial frost pattern or only at the inlet suggests low charge or restriction.
  • Thermistor verification: Test the evaporator thermistor to rule out a sensor error causing false E11 codes.
  • Call a professional: If a sealed system issue is suspected, contact an authorized Hansa service provider to locate leaks, evacuate, and recharge the system or replace the compressor as needed.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Filter-Drier / Capillary Tube (sealed system components)