E17
Hansa Cabinet / Ambient Temperature Sensor Fault

Ice maker shows E17; internal ambient temperature sensor reports out-of-range values, affecting ice production timing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient thermistor, Sensor dislodged from mounting location, Damaged sensor wiring, Control board sensor input failure

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing internal sensors.

  • Locate ambient sensor: Find the thermistor usually mounted near the air intake or inside the cabinet away from the evaporator.
  • Check mounting: Ensure the sensor is properly clipped or secured in its bracket and not touching very cold or hot surfaces that could skew readings.
  • Inspect wiring: Follow the sensor leads to the control board, checking for cuts, pinches, or loose connectors.
  • Measure resistance: With the sensor disconnected, measure resistance and compare to Hansa's temperature-resistance chart. Replace if readings are open, shorted, or far off spec.
  • Control board evaluation: If the sensor is good but E17 remains, the control board's sensor circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements