E18
Hansa
Door / Lid Switch Fault
Display shows E18; ice maker detects that the door or bin access panel is open and will not run, even when it is closed.
Advertisements
Possible Causes
Misaligned door switch actuator, Failed magnetic reed switch or micro-switch, Broken switch bracket, Disconnected switch wiring
How to Fix / Troubleshooting
Safety first: Unplug the ice maker before adjusting switches.
- Locate door switch: Identify the switch near the bin door or top lid. It may be a plunger-style micro-switch or a magnetic reed sensor.
- Check alignment: Ensure the door or lid fully engages the switch when closed. Adjust the door hinges or switch bracket so the actuator is fully depressed or the magnet is properly aligned.
- Test switch: Disconnect the switch and check continuity while opening and closing the door. Replace if it does not change state reliably.
- Inspect wiring: Verify the switch harness is intact and firmly connected to the control board.
- Re-test operation: After repair, close the door firmly and confirm that the E18 code clears and the unit starts a cycle.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door / Lid Switch
Check Price on Amazon