E11
Hisense
Water Level Sensor / Float Switch Error
Hisense ice maker shows E11; unit may beep and stop, often associated with abnormal water level readings.
Advertisements
Possible Causes
Stuck or scaled float, Failed electronic water level sensor, Loose sensor wiring, Contaminated reservoir causing sensor misread
How to Fix / Troubleshooting
Safety: Unplug the unit and drain water from the reservoir.
- Access the reservoir: Remove the top or front cover to expose the water tank and float or level sensor.
- Clean the float: If a mechanical float is used, remove it and clean off mineral deposits or slime with warm water and mild detergent. Ensure it moves freely.
- Inspect electronic sensor: For probe-type sensors, clean the probes with a soft cloth to remove scale.
- Check wiring: Verify the sensor harness is firmly connected and not damaged.
- Test sensor: Use a multimeter to check continuity of a float switch or follow Hisense resistance/voltage specs for electronic sensors. Replace if readings are incorrect.
- Refill and test: Reassemble, refill with clean water, and restart the unit to see if E11 clears.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Level Sensor / Float Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements