E17
Hisense Low Refrigerant / Cooling Performance Error (sensor-based)

Hisense ice maker shows E17; unit may run but produce very little or no ice.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in evaporator or tubing, Weak compressor, Blocked capillary tube or filter-drier, Faulty pressure or temperature sensing logic

How to Fix / Troubleshooting

Safety: Do not attempt to open the sealed refrigeration system unless you are certified. Unplug the unit before inspection.

  • Check evaporator frost pattern: Remove the internal panel and observe the evaporator during operation. A partial frost pattern or only a small section icing indicates a sealed-system issue.
  • Listen to compressor: Ensure the compressor runs steadily without excessive clicking or overheating.
  • Inspect for oil stains: Look for oily residue on tubing joints, which can indicate a refrigerant leak.
  • Basic cleaning: Clean condenser coils and ensure fans are working to rule out airflow issues.
  • Professional service: If E17 persists and cooling is poor, contact a qualified refrigeration technician to check pressures, locate leaks, and recharge or repair the system.
Advertisements

Repair Difficulty

Professional Required 5/5